Sign In | Join Free | My chinacsw.com |
|
Brand Name : GENY
Model Number : YC1893D
Certification : ISO, CE
Place of Origin : CHINA
MOQ : 1 pcs
Price : negotiation
Payment Terms : L/C,T/T,D/P
Supply Ability : 30 PCS per month
Delivery Time : 30 days after order confirmed
Packaging Details : plywood case
Usage : Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment : Three-phase Three-wire
Theory : Electronic Meter
Voltage supply : 3x220/380V±10%(or customized) 50/60Hz ±2Hz
1. Supports all regional wiring configurations: 3-phase 4-wire (3P4W), 3-phase 3-wire (3P3W) and single-phase 2-wire (1P2W) meters.
2. One platform accommodates ferrite-disc mechanical, electro-mechanical and fully electronic meters with selectable automatic, semi-automatic or manual test sequences.
3. Parallel testing of meters sharing identical specifications but differing meter constants—cuts batch time and labour cost.
4. Automatic optical detection of mechanical meter rotor marks increases throughput and removes operator dependency.
5. Comprehensive test modes: active energy, reactive energy and cross-phase reactive energy verification.
6. Optional neutral-current measurement for tamper detection and regulatory compliance.
7. Built-in starting and no-load (creep) tests per IEC/ANSI standards.
8. Optional ICT (Isolated Current Transformer) at every position enables secure testing of 3-phase meters with internal I-P (current-voltage) links still closed.
9. Full protection against overload, shorted voltage circuits and open current circuits safeguards both operator and asset.
10. Lightweight, robust aluminium-alloy frame resists corrosion in tropical environments.
11. Synchronised swing-arm optical probes streamline set-up and reduce handling time.
12. User-friendly Windows-based software (Win 2000/XP/7/8/10) covers every modern meter function: error test, harmonic analysis, maximum-demand verification, influence quantities, etc.
Technical spec. | YC1893D-ICT-6 | YC1893D-ICT-12 | YC1893D-ICT-24 | YC1893D-ICT-48 |
Number of meter positions equipped ICT | 6 | 12 | 24 | 48 |
Accuracy class of ICT | 0.05 / 0.01 | |||
Accuracy | 0.05 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 (customized) | |||
Scanning Head | YCG-S Series | |||
Voltage | | |||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | | |||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | | |||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | | |||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | | |||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | | |||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |
![]() |