Sign In | Join Free | My chinacsw.com
China Guangzhou GENY Electric Co., Ltd logo
Guangzhou GENY Electric Co., Ltd
Professional in Energy Meter Testing
Verified Supplier

2 Years

Home > Energy Meter Automatic Test Pipeline >

0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline

Brand Name : GENY

Model Number : YCATS II

Certification : ISO, CE

Place of Origin : China

MOQ : 1

Price : negotiate rates

Payment Terms : T/T, L/C, D/P, T/T

Supply Ability : 2 sets/ 3 months

Delivery Time : 6~8weeks

Packaging Details : Plywood cases

Communication Protocol : Modbus RTU, Modbus TCP, DNP3.0

Control Software : Graphical user interface (GUI)

Dimensions : Customizable based on customer's requirements

Test Frequency : 50Hz/60Hz

Accuracy Level : 0.05%, 0.1%, 0.2%

Testing Standards : IEC 62053-21, IEC 62053-22, IEC 62053-23

Power Supply : 220V/110V, 50Hz/60Hz

Application : Energy meter testing

Operating System : Windows

Test Voltage Range : 0-500V

Test Current Range : 0-200A

Function : Automatically test energy meters for accuracy and functionality

Contact Now

Energy Meter Automatic Test Pipeline Error: Initiating creeping and time base testing.

Poly Phase Energy Meter Automatic Test Pipeline: Initiating closed link testing for easy expansion of PC control.

Product Description:

This is a 3-phase automatic test line featuring a power cabinet (model: YC1893D) and 20 test stations. Each station is equipped with an Isolated Current Transformer (ICT model: TICT-100) for independent operation. The automated system utilizes pneumatic drive and includes a robotic arm.

Features:

  • Accuracy: 0.05% / 0.02%
  • Each meter position unit with a power source and connect in parallel. The unit is totally separated, don't affect each other, eliminating the effect of large power output in stability of power source reducing error, and improving test accuracy.
  • The breakdown of power source of MUT only affects one meter position unit, and the other positions still work normally, so the system is more reliable.
  • More meter position, less installation waiting time. Effective test time is shorter, only 30% of conventional test Methods.
  • The meter with different testing ranges, constants protocols can be tested together because each meter position unit are in parallel, which does not affect each other.
  • Test poly phase meter with closed link. Expansion of meter position units is easy and convenient.
  • Automatic meter loading /unloading and test, with PC control by Ethernet communication.
  • Flow of work: meter loading, indentation, location, testing, defect sorting, labeling, lead sealing, packaging, Return to meter's warehouse.

Functions:

  • Features & Functions
  • Error Testing: Precise measurement of meter accuracy.
  • Start-Up and Creep Testing: Evaluation of meter response to low power levels.
  • Time Base Testing: Assessment of timekeeping accuracy.
  • Time Consumption Switch Testing: Verification of time-based switching functionality.
  • Demand Testing: Measurement of peak power usage.
  • Dielectric Withstand Voltage Testing: Evaluation of insulation integrity.
  • Influence Testing: Analysis of external factors on meter performance.
  • Dial Testing: Inspection of mechanical dial functionality and accuracy.

Application Conditions and Requirements

Environment Power Requirement Safety
Operation
Temperature
Humidity Altitude Voltage Supply IP Class Conformity
-10°C--+40ºC 35%--85% <2500m 3x220/380V±10%
(or customized)
50/60Hz±2Hz
IP30 CE conform
Type YCS-103-250 YCS-103-800 YCS-103-1200 YCS-203-2500
Voltage
Test voltage output(Phase-Neutral) 3x(24V-300V)(or customized)
Power of the voltage output Max.3x100VA Max.3x250VA Max.3x500VA Max.3x1000VA
Resolution Better than 0.01%of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h(integration time 150 s)
Load regulation from 0-max.load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd-41st free programmable
Current
Test current output 3x(1mA-120A/200A)
Power of the current output Max.3x250VA Max.3x500VA Max.3x1000VA Max.3x2000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05%at the final range value
Stability Better than 0.005%/h(integration time 150 s)
Load regulation from 0-max.load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd-41st free programmable
Phase angle
Range 0-360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz-65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits

*If you want to know more please check our official website:http://www.genymetertestequipment.com/

0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline

0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline


Product Tags:

Polyphase Energy Meter Automatic Test Pipeline

      

Accuracy Energy Meter Automatic Test Pipeline

      
Quality 0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline for sale

0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0